<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ixxat.de &#187; Modbus-TCP</title>
	<atom:link href="http://www.ixxat.de/blog/category/modbus-tcp/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.ixxat.de/blog</link>
	<description></description>
	<lastBuildDate>Mon, 30 Jan 2012 13:07:12 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>Seminare für CAN und Industrial Ethernet</title>
		<link>http://www.ixxat.de/blog/canopen/seminare-fur-can-und-industrial-ethernet/</link>
		<comments>http://www.ixxat.de/blog/canopen/seminare-fur-can-und-industrial-ethernet/#comments</comments>
		<pubDate>Tue, 11 Jan 2011 16:15:07 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[CAN]]></category>
		<category><![CDATA[CANopen]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Events]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/?p=381</guid>
		<description><![CDATA[Aktuelle Seminartermine im März: - CAN-Seminar &#8211; 05.04.2011 - Analyse von CAN-Netzwerken &#8211; 06.04.2011 - CANopen-Seminar &#8211; 07.04.2011 - Real-time Ethernet Seminar &#8211; 29.3.2011 - EtherNet/IP-Seminar &#8211; 30.-31.03.2011 Neben Standard-Seminaren bietet IXXAT auch In-House-Seminare an. Hierbei sind sowohl eintägige als auch mehrtägige Seminare möglich, die in deutscher oder englischer Sprache gehalten werden. Weitere Informationen zu [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignleft size-full wp-image-80" style="border: 0pt none; margin: 0px 10px;" title="Seminare für CAN, CANopen und EtherNet/IP" src="http://www.ixxat.de/blog/wp-content/uploads/2009/02/blog-seminare.gif" alt="" width="150" height="150" /><strong>Aktuelle Seminartermine im März:<br />
</strong><br />
- CAN-Seminar &#8211; 05.04.2011<br />
- Analyse von CAN-Netzwerken &#8211; 06.04.2011<br />
- CANopen-Seminar &#8211; 07.04.2011<br />
- Real-time Ethernet Seminar &#8211; 29.3.2011<br />
- EtherNet/IP-Seminar &#8211; 30.-31.03.2011</p>
<p>Neben Standard-Seminaren bietet IXXAT auch In-House-Seminare an. Hierbei sind sowohl eintägige als auch mehrtägige Seminare möglich, die in deutscher oder englischer Sprache gehalten werden.<br />
Weitere Informationen zu unseren Seminaren finden Sie im Internet unter</p>
<p><a title="Seminare" href="http://www.ixxat.de/seminare" target="_blank">www.ixxat.de/seminare</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/canopen/seminare-fur-can-und-industrial-ethernet/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Real-time Ethernet Seminar</title>
		<link>http://www.ixxat.de/blog/profinet/real-time-ethernet-seminar/</link>
		<comments>http://www.ixxat.de/blog/profinet/real-time-ethernet-seminar/#comments</comments>
		<pubDate>Thu, 21 Jan 2010 07:25:07 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[EtherCAT]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Events]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>
		<category><![CDATA[Ethernet]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Industrial Ethernet]]></category>
		<category><![CDATA[Real-time]]></category>
		<category><![CDATA[Seminar]]></category>
		<category><![CDATA[SERCOS]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/allgemein/real-time-ethernet-seminar/</guid>
		<description><![CDATA[Einführung, Protokolle und Implementierung Mit dem neuen eintägigen Real-time Ethernet Seminar greift IXXAT ein aktuelles Thema auf und ermöglicht es sowohl Entwicklern also auch Entscheidern sich einen schnellen Überblick über die wichtigen aktuell verfügbaren Protokolle sowie deren spezifische Eigenschaften und Besonderheiten bei der Implementierung zu verschaffen. Im Seminar werden die Protokolle EtherNet/IP, Profinet RT &#38; [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Real time Industrial Ethernet Seminar" href="http://www.ixxat.de/blog/wp-content/uploads/2010/01/blog-real-time-ethernet-sem.gif" class="fancybox"><img src="http://www.ixxat.de/blog/wp-content/uploads/2010/01/blog-real-time-ethernet-sem.gif" border="0" alt="Real time Industrial Ethernet Seminar" hspace="10" vspace="0" width="150" height="114" align="left" /></a><strong>Einführung, Protokolle und Implementierung</strong></p>
<p>Mit dem neuen eintägigen Real-time Ethernet Seminar greift IXXAT ein aktuelles Thema auf und ermöglicht es sowohl Entwicklern also auch Entscheidern sich einen schnellen Überblick über die wichtigen aktuell verfügbaren Protokolle sowie deren spezifische Eigenschaften und Besonderheiten bei der Implementierung zu verschaffen.</p>
<p>Im Seminar werden die Protokolle EtherNet/IP, Profinet RT &amp; IRT, POWERLINK, EtherCAT, und SERCOS III vorgestellt. Hierbei werden neben den funktionalen Kriterien, wie z. B. die erreichbare Echtzeitfähigkeit, Modellierung der Prozess- und Parameterdaten sowie der Datenübertragungsfunktionen, auch Implementierungsmöglichkeiten, Erweiterungsfähigkeit, Flexibilität sowie die Verbreitung der Protokolle behandelt.</p>
<p><span id="more-119"></span>All diese Kriterien spielen bei der Auswahl eines Protokolles eine wesentliche Rolle.<br />
Darüber hinaus werden typische Einsatzbereiche sowie Stärken und Schwächen der verschiedenen Lösungen angesprochen.</p>
<p>Mit dem Seminar erhalten die Seminarteilnehmer von neutraler Stelle einen kompetenten und schnellen Einstieg in die Technologie der neuen industriellen Ethernet-Feldbusprotokolle.</p>
<p>Seit bereits über 20 Jahren bietet IXXAT Seminare im Bereich der industriellen und automotiven Daten-kommunikation an. Dieses und weitere Seminare, z. B. für CAN, CANopen, EtherNet/IP und FlexRay, bietet IXXAT auf Wunsch in einer auf die Kundenbedürfnisse angepassten Version als In-House-Seminar in deutscher oder englischer Sprache an.</p>
<p>Seminartermine: 25. März 2010 und 22. Sept. 2010.</p>
<p>Weitere Informationen zum neuen Real-time Ethernet Seminar finden Sie unter <a title="Industrial Real Time Ethernet Seminar" href="http://www.ixxat.de/industrial-real-time-ethernet-seminar_de.html" target="_blank">www.ixxat.de/seminare</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/profinet/real-time-ethernet-seminar/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Industrial Ethernet Modul mit integriertem Switch</title>
		<link>http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul-mit-integriertem-switch/</link>
		<comments>http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul-mit-integriertem-switch/#comments</comments>
		<pubDate>Fri, 25 Sep 2009 11:25:04 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[EtherCAT]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[Produkte]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>
		<category><![CDATA[Ethernet]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Industrial Ethernet]]></category>
		<category><![CDATA[Industrial Ethernet Modul]]></category>
		<category><![CDATA[Interface]]></category>
		<category><![CDATA[Modul]]></category>
		<category><![CDATA[Real-time]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul-mit-integriertem-switch/</guid>
		<description><![CDATA[IXXATs Industrial Ethernet Modul (IEM) ermöglicht eine kostengünstige und leistungsfähige Linientopologie durch die im FPGA integrierte, hochperformante Switch-IP. Das IEM realisiert eine kostengünstige und flexible Anbindung an unterschiedliche Industrial Ethernet Technologien. Es basiert auf einem leistungsfähigen Altera Cyclone III FPGA und verfügt neben einer integrierten 32-Bit CPU, PHYs, Übertragern und RJ45-Buchsen nun auch über einen [...]]]></description>
			<content:encoded><![CDATA[<p><a title="IP Switch für Industrial Ethernet Modul" href="http://www.ixxat.de/blog/wp-content/uploads/2009/09/blog_iem_switch_ip.gif" class="fancybox"><img src="http://www.ixxat.de/blog/wp-content/uploads/2009/09/blog_iem_switch_ip.gif" border="0" alt="IP Switch für Industrial Ethernet Modul" hspace="10" vspace="0" width="150" height="146" align="left" /></a><strong>IXXATs Industrial Ethernet Modul (IEM) ermöglicht eine kostengünstige und leistungsfähige Linientopologie durch die im FPGA integrierte, hochperformante Switch-IP.</strong></p>
<p>Das IEM realisiert eine kostengünstige und flexible Anbindung an unterschiedliche Industrial Ethernet Technologien. Es basiert auf einem leistungsfähigen Altera Cyclone III FPGA und verfügt neben einer integrierten 32-Bit CPU, PHYs, Übertragern und RJ45-Buchsen nun auch über einen integrierten 3-Port-Switch, welcher bei Profinet, EtherNet/IP und Modbus-TCP eingesetzt wird.<br />
<span id="more-110"></span> Die Switch-IP wurde von IXXAT in enger Zusamenarbeit mit einem führenden Hersteller von Ethernet Switches entwickelt. Die IP realisiert einen Store-And-Forward Switch und ist speziell für den Einsatz in Echtzeit-Ethernet-Netzwerken entwickelt worden. Eine Implementierung als Cut-Through Switch ist in Vorbereitung.<br />
Die Switch-IP nutzt unterschiedliche Prioritäten um Real-time Ethernet-Nachrichten mit geringster Latenz und niedrigem Jitter (im unteren Microsekundenbereich) zu übertragen.<br />
Die Switch-IP verfügt über integrierte MACs und unterstützt 10/100Base-T, halb- und vollduplex.<br />
Über das Management-Interface der Switch-IP lassen sich verschiedenste Modi des Switches konfigurieren, beispielsweise statische oder selbstlernende Adresstabelle, Aging-Methode, variables und festes Routing, etc. Weiterhin unterstützt der interne Port verschiedenste Filtermodi sowie Backpressure und reduziert somit die Belastung des angeschlossenen Systems.</p>
<p>Die Switch-IP ist als Produkt für FPGAs der Altera Cyclone III Familie verfügbar (weitere FPGA-Typen auf Anfrage). Selbstverständlich bietet IXXAT auch kundenspezifische Anpassungen der Switch-IP auf Projektbasis an.</p>
<p><a title="Industrial Ethernet Modul" href="http://www.ixxat.de/industrial-ethernet-module_de.html" target="_blank">Weitere Informationen zum Industrial Ethernet Modul </a></p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul-mit-integriertem-switch/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Modbus-TCP Server Protokollsoftware</title>
		<link>http://www.ixxat.de/blog/neue-produkte/modbus-tcp-slave-protokollsoftware/</link>
		<comments>http://www.ixxat.de/blog/neue-produkte/modbus-tcp-slave-protokollsoftware/#comments</comments>
		<pubDate>Thu, 18 Jun 2009 11:25:51 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[Produkte]]></category>
		<category><![CDATA[Protokollsoftware]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/neue-produkte/modbus-tcp-slave-protokollsoftware/</guid>
		<description><![CDATA[Mit dem neuen Modbus-TCP Stack bietet IXXAT ab sofort ein leistungsstarkes Softwarepaket für die schnelle und einfache Entwicklung von Modbus-TCP Server-Geräten an. Die Software unterstützt hierbei sowohl die Conformance Klassen 0 und 1 als auch Teile der Klasse 2. Um eine optimale Integration der Protokollsoftware in die Kundenanwendung zu gewährleisten, stehen dem Anwender zahlreiche Möglichkeiten [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Modbus-TCP/IP Logo" href="http://www.ixxat.de/blog/wp-content/uploads/2009/06/blog-modbus-tcp.gif" class="fancybox"><img src="http://www.ixxat.de/blog/wp-content/uploads/2009/06/blog-modbus-tcp.gif" border="0" alt="Modbus-TCP/IP Logo" hspace="10" vspace="0" width="150" height="50" align="left" /></a>Mit dem neuen Modbus-TCP Stack bietet IXXAT ab sofort ein leistungsstarkes Softwarepaket für die schnelle und einfache Entwicklung von Modbus-TCP Server-Geräten an. Die Software unterstützt hierbei sowohl die Conformance Klassen 0 und 1 als auch Teile der Klasse 2.</p>
<p>Um eine optimale Integration der Protokollsoftware in die Kundenanwendung zu gewährleisten, stehen dem Anwender zahlreiche Möglichkeiten zur Konfiguration und Anpassung zur Verfügung. So kann z.B. die Verwaltung der Primary Table Daten sowohl innerhalb des Stacks als auch direkt durch die Kundenanwendung erfolgen.</p>
<p><span id="more-101"></span></p>
<p>Durch getrennte Abstraktionsschichten für das Betriebssystem und die TCP/IP Software kann die Modbus-TCP Server Protokollsoftware schnell und einfach an unterschiedliche Prozessoren oder Betriebssysteme angepasst werden.</p>
<p>Die Software wird als Produktlizenz im Quellcode vertrieben. Ein im Lieferumfang<br />
enthaltenes Demoprogramm für Windows 2000/XP sowie das ausführliche Benutzerhandbuch und Beispielprogramme ermöglichen einen schnellen Start der Entwicklung.</p>
<p><a title="Modbus-TCP Slave (Server) Protokoll Software" href="http://www.ixxat.de/modbus-tcp-protocol-software-stack_de.html" target="_blank">&#8230; lesen Sie mehr </a></p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/neue-produkte/modbus-tcp-slave-protokollsoftware/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Implementierung von Industrial Ethernet</title>
		<link>http://www.ixxat.de/blog/fachartikel/implementierung-von-industrial-ethernet-schnittstellen/</link>
		<comments>http://www.ixxat.de/blog/fachartikel/implementierung-von-industrial-ethernet-schnittstellen/#comments</comments>
		<pubDate>Mon, 25 May 2009 08:28:47 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[EtherCAT]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Fachartikel]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>
		<category><![CDATA[Ethernet]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Modul]]></category>
		<category><![CDATA[Real-time]]></category>
		<category><![CDATA[SERCOS]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/fachartikel/implementierung-von-industrial-ethernet-schnittstellen/</guid>
		<description><![CDATA[Von Christian Schlegel, IXXAT Automation GmbH Der Markt verlangt zunehmend nach Geräten mit Ethernet-basierten Kommunikationsschnittstellen. Da es wie bei den klassischen Feldbussen auch bei Real-Time Industrial Ethernet nicht nur ein Protokoll gibt, das von Geräteherstellern unterstützt werden muss, Ethernet jedoch nicht gleich Ethernet ist, sind Lösungen zur Integration der verschiedenen Industrial Ethernet Protokolle gefragt, welche [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Industrial Ethernet Modul" href="http://www.ixxat.de/blog/wp-content/uploads/2009/05/blog_article_industrial_ethernet_module.jpg" class="fancybox"><img src="http://www.ixxat.de/blog/wp-content/uploads/2009/05/blog_article_industrial_ethernet_module.jpg" border="0" alt="Industrial Ethernet Modul" hspace="10" vspace="0" width="150" height="90" align="left" /></a><em>Von Christian Schlegel, IXXAT Automation GmbH</em></p>
<p>Der Markt verlangt zunehmend nach Geräten mit Ethernet-basierten Kommunikationsschnittstellen. Da es wie bei den klassischen Feldbussen auch bei Real-Time Industrial Ethernet nicht nur ein Protokoll gibt, das von Geräteherstellern unterstützt werden muss, Ethernet jedoch nicht gleich Ethernet ist, sind Lösungen zur Integration der verschiedenen Industrial Ethernet Protokolle gefragt, welche die Anzahl der verschiedenen Ethernet-Anschaltungen minimieren und damit den Hardwareaufwand als auch den Softwareaufwand minimieren.</p>
<p>Obwohl es mit den Bemühungen der IAONA bereits kurz nach dem ersten Aufkommen von industriellen, Ethernet-basierenden Kommunikationssystemen den Versuch gab, eine möglichst einheitliche Lösung für die industrielle Kommunikation auf Basis von Ethernet zu finden, gibt es in der Zwischenzeit eine Vielzahl von Lösungsansätzen. In der IEC 61158 sind derzeit 11 Lösungen standardisiert, die aber lediglich auf der physikalischen Ebene zueinander kompatibel sind und auf teilweise völlig unterschiedlichen Lösungsansätzen beruhen. Wie im Anschluss an den in den achtziger Jahren tobenden sog. &#8220;Feldbuskrieg&#8221;, werden sich letztlich wieder einige Lösungen als wirklich marktfähig erweisen. Neben den Lösungen Profinet und Ethernet/IP der Marktführer für Automatisierungstechnik Siemens/PNO und Rockwell/ODVA ist abzusehen, dass sich im europäischen Raum noch die Lösungen EtherCAT (Beckhoff/ETG), POWERLINK (B &amp; R/EPSG) sowie Sercos III (Bosch-Rexroth/ITG) durchsetzen werden.</p>
<p><a title="Implementierung von Industrial Ethernet Schnittstellen" href="http://www.ixxat.de/article-real-time-industrial-ethernet-modul_de.html" target="_blank">&#8230; lesen Sie mehr</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/fachartikel/implementierung-von-industrial-ethernet-schnittstellen/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Neues Industrial Ethernet  Modul von IXXAT</title>
		<link>http://www.ixxat.de/blog/neue-produkte/neues-industrial-ethernet-modul-von-ixxat/</link>
		<comments>http://www.ixxat.de/blog/neue-produkte/neues-industrial-ethernet-modul-von-ixxat/#comments</comments>
		<pubDate>Tue, 14 Oct 2008 06:06:52 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[EtherCAT]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[Produkte]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>
		<category><![CDATA[API]]></category>
		<category><![CDATA[Industrial Ethernet]]></category>
		<category><![CDATA[Industrial Ethernet Modul]]></category>
		<category><![CDATA[Modul]]></category>
		<category><![CDATA[SERCOS]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/neue-produkte/neues-industrial-ethernet-modul-von-ixxat/</guid>
		<description><![CDATA[Unterstützung aller wichtigen Industrial Ethernet Protokolle. Auf der diesjährigen SPS/IPC/DRIVES in Nürnberg stellt IXXAT das neue Industrial Ethernet Modul vor, das den Kunden die einfache Anbindung ihres Geräts an Netzwerke ermöglicht, die auf einem industriellen Ethernet Standard basieren. Das neue Industrial Ethernet Modul wurde von Grund auf für den Einsatz mit den verschiedensten Protokollstandards entworfen. [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Real-time Industrial Ethernet Modul" href="http://www.ixxat.de/blog/wp-content/uploads/2008/10/blog-industrial-ethernet-mo.gif" class="fancybox"><img src="http://www.ixxat.de/blog/wp-content/uploads/2008/10/blog-industrial-ethernet-mo.gif" border="0" alt="Real-time Industrial Ethernet Modul" hspace="10" width="150" height="133" align="left" /></a><strong>Unterstützung aller wichtigen Industrial Ethernet Protokolle.</strong></p>
<p>Auf der diesjährigen SPS/IPC/DRIVES in Nürnberg stellt IXXAT das neue Industrial Ethernet Modul vor, das den Kunden die einfache Anbindung ihres Geräts an Netzwerke ermöglicht, die auf einem industriellen Ethernet Standard basieren.</p>
<p>Das neue Industrial Ethernet Modul wurde von Grund auf für den Einsatz mit den verschiedensten Protokollstandards entworfen.<br />
Hierbei kommt ein leistungsfähiges Altera Cyclone III FPGA zum Einsatz und es wurde besonderer Wert auf niedrige Herstellkosten für das Modul gelegt.<br />
Das neue Industrial Ethernet Modul ist damit leistungsfähiger, preisgünstiger, kleiner und universeller einsetzbar als das Vorgängermodell.<br />
<span id="more-63"></span></p>
<p>Das IXXAT Industrial Ethernet Modul wird mit den Protokollen Powerlink, PROFINET, EtherNet/IP, EtherCAT und SERCOS III angeboten, von denen einige bereits zur SPS/IPC/DRIVES auf dem Modul verfügbar sein werden. Die Lieferung erfolgt dabei inklusive einer protokollunabhängigen Host-API, die den einfachen Wechsel des Protokolls ohne große Änderungen an der Kundenapplikation ermöglicht. Voraussichtlich bis Ende des Jahres wird unter Anderem auch ein in das FPGA integrierter Ethernet Switch auf dem Modul verfügbar sein.</p>
<p>Für das Modul ist bei IXXAT ein Evaluation Kit verfügbar, das neben Software und Dokumentation auch ein Trägerboard und Adapterboards für den Anschluss verschiedener CPU Module beinhaltet.</p>
<p>Falls der Formfaktor des Industrial Ethernet Moduls für die Integration in das Kundengerät nicht geeignet ist, bietet IXXAT auch eine Design-In Lösung an. Darüber hinaus realisiert IXXAT selbstverständlich auch vollständig kundenspezifische Lösungen auf Projektbasis.</p>
<p>[<a title="Real-time Industrial Ethernet Modul" href="http://www.ixxat.de/industrial-ethernet-module_de.html" target="_blank">Lesen Sie mehr auf der IXXAT Webseite</a>]</p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/neue-produkte/neues-industrial-ethernet-modul-von-ixxat/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fachartikel zur Real-Time-Ethernet Implementierung</title>
		<link>http://www.ixxat.de/blog/fachartikel/fachartikel-zur-real-time-ethernet-implementierung/</link>
		<comments>http://www.ixxat.de/blog/fachartikel/fachartikel-zur-real-time-ethernet-implementierung/#comments</comments>
		<pubDate>Wed, 16 Apr 2008 13:47:25 +0000</pubDate>
		<dc:creator>pastors</dc:creator>
				<category><![CDATA[EtherCAT]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Fachartikel]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/fachartikel/fachartikel-zur-real-time-ethernet-implementierung/</guid>
		<description><![CDATA[Implementierung von Real-Time Industrial Ethernet Schnittstellen &#8211; universelle Lösung auf Basis der FPGA-Technologie Der Markt verlangt zunehmend nach Geräten mit Ethernet-basierten Kommunikationsschnittstellen. Da es wie bei den klassischen Feldbussen auch bei Real-Time Industrial Ethernet nicht nur ein Protokoll gibt, das von Geräteherstellern unterstützt werden muss, Ethernet jedoch nicht gleich Ethernet ist, sind Lösungen zur Integration [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Implementierung von Industrial Ethernet Protokollen" href="http://www.ixxat.de/blog/wp-content/uploads/2008/04/blog-industrial-ethernet-implementation.gif" class="fancybox"><img src="http://www.ixxat.de/blog/wp-content/uploads/2008/04/blog-industrial-ethernet-implementation.gif" border="0" alt="Implementierung von Industrial Ethernet Protokollen" hspace="10" width="150" height="101" align="left" /></a><strong>Implementierung von Real-Time Industrial Ethernet Schnittstellen &#8211; universelle Lösung auf Basis der FPGA-Technologie</strong></p>
<p>Der Markt verlangt zunehmend nach Geräten mit Ethernet-basierten Kommunikationsschnittstellen. Da es wie bei den klassischen Feldbussen auch bei Real-Time Industrial Ethernet nicht nur ein Protokoll gibt, das von Geräteherstellern unterstützt werden muss, Ethernet jedoch nicht gleich Ethernet ist, sind Lösungen zur Integration der verschiedenen Industrial Ethernet Protokolle gefragt, welche die Anzahl der verschiedenen Ethernet-Anschaltungen minimieren und damit den Hardwareaufwand als auch den Softwareaufwand minimieren.<br />
<span id="more-44"></span><strong><br />
Vielfältige Systemlösungen</strong><br />
Obwohl es mit den Bemühungen der IAONA bereits kurz nach dem ersten Aufkommen von industriellen, Ethernet-basierenden Kommunikationssystemen den Versuch gab, eine möglichst einheitliche Lösung für die industrielle Kommunikation auf Basis von Ethernet zu finden, gibt es in der Zwischenzeit eine Vielzahl von Lösungsansätzen. In der IEC 61158 sind derzeit 11 Lösungen standardisiert, die aber lediglich auf der physikalischen Ebene zueinander kompatibel sind und auf teilweise völlig unterschiedlichen Lösungsansätzen beruhen. Wie im Anschluss an den in den achtziger Jahren tobenden sog. &#8220;Feldbuskrieg&#8221;, werden sich letztlich wieder einige Lösungen als wirklich marktfähig erweisen. Neben den Lösungen Profinet und Ethernet/IP der Marktführer für Automatisierungstechnik Siemens/PNO und Rockwell/ODVA ist abzusehen, dass sich im europäischen Raum noch die Lösungen EtherCAT (Beckhoff/ETG), Powerlink (B &amp; R/EPSG) sowie Sercos III (Bosch-Rexroth/ITG) durchsetzen werden.</p>
<p><a title="Fachartikel - Implementierung von Powerlink, Profinet, EtherCAT und EtherNet/IP" href="http://www.ixxat.de/article-real-time-industrial-ethernet-modul_de.html" target="_blank">Lesen Sie den ganzen Artikel auf der IXXAT Webseite</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/fachartikel/fachartikel-zur-real-time-ethernet-implementierung/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Industrial Ethernet Modul</title>
		<link>http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul/</link>
		<comments>http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul/#comments</comments>
		<pubDate>Tue, 16 Oct 2007 15:11:59 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[EtherCAT]]></category>
		<category><![CDATA[EtherNet/IP]]></category>
		<category><![CDATA[Modbus-TCP]]></category>
		<category><![CDATA[POWERLINK]]></category>
		<category><![CDATA[Produkte]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[SERCOS III]]></category>
		<category><![CDATA[Modul]]></category>
		<category><![CDATA[SERCOS]]></category>

		<guid isPermaLink="false">http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul/</guid>
		<description><![CDATA[Industrial Ethernet Modul für PROFINET, EtherCAT, EtherNet/IP und Powerlink Mit dem bewährten &#8220;Industrial Ethernet Modul&#8221; von IXXAT können Geräte schnell und kostengünstig an die verschiedenen Industrial Ethernet Technologien angebunden werden. Neben der bisher schon verfügbaren Variante für Powerlink Controlled Node unterstützt das Modul nun auch PROFINET RT IO-Device, EtherCAT Slave und EtherNet/IP Adapter. Als weitere [...]]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.ixxat.de/blog/wp-content/uploads/2008/02/blog_industrial_ethernet_mo.gif" border="0" alt="blog_industrial_ethernet_mo.gif" hspace="10" align="left" />Industrial Ethernet Modul für PROFINET, EtherCAT, EtherNet/IP und Powerlink</p>
<p>Mit dem bewährten &#8220;Industrial Ethernet Modul&#8221; von IXXAT können Geräte schnell und kostengünstig an die verschiedenen Industrial Ethernet Technologien angebunden werden.</p>
<p><span id="more-10"></span></p>
<p>Neben der bisher schon verfügbaren Variante für Powerlink Controlled Node unterstützt das Modul nun auch PROFINET RT IO-Device, EtherCAT Slave und EtherNet/IP Adapter. Als weitere Technologien sind SERCOS III und Modbus/TCP in Vorbereitung.</p>
<p><a title="Industrial Ethernet Modul Flyer" href="http://www.ixxat.de/download/flyer_iem.pdf" target="_blank">Weitere Informationen zum Flyer finden Sie hier</a></p>
<p><a title="Industrial Ethernet Modul" href="http://www.ixxat.de/index.php?seite=powerlink_module_de" target="_blank">Weitere Informationen zum Industrial Ethernet Modul finden Sie hier</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.ixxat.de/blog/neue-produkte/industrial-ethernet-modul/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

